Welcome to Hong Kong CAS Testing ~

lang  CN

Our Services

Clean heating equipment scrap identification

Clean heating equipment scrap identification-Asset Decommissioning-

Cleaning and heating equipment scrappedAppraisal Background

The main types of clean heating equipment are hot water air source heat pumps, hot air air source heat pumps (hot air fans), and gas wall-mounted boilers. The scrapping identification of clean heating equipment includes air source heat pumps and energy storage electric heaters that have been converted from coal to electricity for more than 10 years, and gas wall-mounted boilers that have been converted from coal to gas for more than 8 years. If they cannot be used normally and have not reached the service life, they have been deemed to meet the scrapping standards.

As an independent third-party appraisal agency under Guoke Holdings, Zhongke Testing has the qualifications for fixed asset scrapping appraisal. Based on the list of assets to be scrapped and assessed and related information provided by the client, it can organize technical personnel to evaluate the assets to be scrapped and evaluate, and issue a clean heating equipment scrapping appraisal report.



Cleaning and heating equipment scrappedScrap Condition

1. General scrap standards

Clean heating equipment has been in operation for 10 years or more (gas wall-mounted boilers have been in operation for 8 years or more) and cannot be used normally or has not reached the useful life but has been deemed to meet the scrap standard.

2. Scrapping standards for main equipment types

(1) Hot water air source heat pump

1. The main components of the equipment (compressor, heat exchanger, condenser, electronic control motherboard, etc.) are replaced and repaired twice a year, affecting normal use;

02. At ambient temperature When the ambient temperature is lower than -12°C, the outlet water temperature cannot reach above 41°C after the device is running;

1

23. When the ambient temperature is lower than -25°C, the device cannot start normally;

3

44. Electricity consumption and operating costs during the heating season exceed 20% of previous years;

5

65. The system performance coefficient during the heating season attenuates to below 2.0.

7

8 (2) Hot air air source heat pump

9

01. When the ambient temperature is -12℃, the air outlet temperature cannot reach above 30℃ after the equipment is running;

1

22. When the ambient temperature is lower than -30℃, the equipment cannot start normally;

3

43. The power consumption during the heating season exceeds 20% of previous years;

5

64. The system performance coefficient during the heating season attenuates below 2.0.

7

8 (3) Gas wall-mounted boiler

9

01. The heat exchanger is leaking or seriously corroded;

1

2 2. The gas consumption during the heating season exceeds 20% of previous years;

3

43. The heating efficiency of the system decreases by more than 20% during the heating season;

5

64. There are safety hazards that are difficult to repair and eliminate.

7

8

9

0

1

2

3

Cleaning and heating equipment scrappedIdentification method

1. Technical testing and evaluation: Conduct comprehensive technical testing and evaluation of the equipment.

2. Maintenance history analysis: Thoroughly analyze and evaluate the maintenance history of the equipment, including maintenance records, replacement parts, maintenance costs, etc. in the past few years, to determine the reliability and maintenance cost of the equipment.

3. Energy efficiency assessment: Evaluate the energy efficiency of the equipment, including evaluating the equipment's energy utilization efficiency, energy consumption, and compliance with current energy efficiency standards.

4. Environmental compliance assessment: Review the environmental protection status of the equipment, including compliance with emission standards, effectiveness of pollution control facilities, etc., to ensure that the equipment will not have a negative impact on the environment during use.


0

1

2

3

Cleaning and heating equipment scrappedAuthentication case

was entrusted by a certain street office to conduct a technical appraisal on whether the cleaning and heating equipment of each household in the street can be scrapped.

identification and analysis results:

The identification and analysis expert group investigated the relevant situation, inspected and photographed the identification objects, and made the following suggestions and conclusions after special inspection and on-site investigation and comprehensive analysis:

The identification objects cannot meet the work needs and have no repair value. It is recommended to apply for scrap disposal.


0

1

2

3

Cleaning and heating equipment scrappedAppraisal Process

Product information confirmation→Collection of original technical data→Reusability judgment→Safety appraisal→Performance appraisal and downgraded use→Life reliability appraisal→Issue appraisal conclusion